LED - Clear a design

LED - Clear a design

How do I CLEAR a design that is currently on my machine in the standard control panel? 

Press the STOP button. Hold down the SET button until the machine beeps rapidly and the LCD screen blinks "Design End Code"
    • Related Articles

    • LED - How do I rotate my design?

      How do I ROTATE my design in the standard control panel? Load the design as normal. Press the SETTING button. Press the DOWN button on the LCD menu indication screen twice to access the ANGLE command. Press the SET button. Change the setting by ...
    • LED - Enlarge or shrink my design

      How do I ENLARGE or SHRINK my design in the standard control panel? Load the design as normal. Press the SETTING button. You will see highlighted "1) X Scale: 100%. Press the SET button. You can type in any percentage increase or decrease you would ...
    • LED - Load a design on the standard control panel

      How do I LOAD a design on the standard control panel? Insert the design disk into the floppy disk drive. The floppy disk drive is located on the right side of the control panel. Press the EMB.CALL button or (IN-OUT button) Press the green DOWN button ...
    • LED - Basic setting

      How do I put in my basic setting on the standard control panel? Go to 1. BASIC SETTING Press the SETTING button. Using the DOWN key to 3. Angle the input 0-for Flat and 180- for Caps. Press the SET button.
    • LED - CAP and FLAT settings

      How do I SWITCH the machine between CAP and FLAT settings in the standard control panel? Press the MACHINE button. Press the DOWN button. The "2) Machine Function" command will be highlighted. Press the SET button. The "1.Flat, Cap: Flat" command ...